{"id":3078,"date":"2023-02-17T15:52:12","date_gmt":"2023-02-17T18:52:12","guid":{"rendered":"http:\/\/desa.inia.cl\/agrometeorologia\/?p=3078"},"modified":"2023-03-01T09:54:31","modified_gmt":"2023-03-01T12:54:31","slug":"instalacion-de-la-unidad-central","status":"publish","type":"post","link":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/2023\/02\/17\/instalacion-de-la-unidad-central\/","title":{"rendered":"Instalaci\u00f3n de la unidad central"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_row column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<h3>1. Datalogger<\/h3>\n<p>La unidad central de procesamiento o CPU de una EMA generalmente est\u00e1 formada por un datalogger, \u00e9ste tiene la labor de recibir cada una de las lecturas de los sensores y almacenar la informaci\u00f3n en la memoria para luego realizar los c\u00e1lculos necesarios de acuerdo con lo establecido en la programaci\u00f3n. Las instrucciones entregadas en este manual consideran a un datalogger Campbell Scientific\u00ae modelo CR1000. Sin embargo, los procedimientos son similares al datalogger CR1000x, el cual est\u00e1 presente en las estaciones m\u00e1s recientes de la red.<\/p>\n<h4>1.1 Datalogger CR1000 Campbell Scientific<\/h4>\n<p>El CR1000 est\u00e1 protegido por una caja met\u00e1lica, en su interior se encuentra la electr\u00f3nica de medici\u00f3n y control. Un resumen de sus caracter\u00edsticas generales se muestra en el Cuadro 1.<\/p>\n<p>[\/et_pb_text][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||5px||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Cuadro 1.<\/strong> Resumen de las caracter\u00edsticas del CR1000.<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/instalacion-datalogger.png&#8221; title_text=&#8221;instalacion datalogger&#8221; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/instalacion-datalogger-1.png&#8221; title_text=&#8221;instalacion datalogger 1&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;10px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Figura 1. <\/strong>Panel de cableado del CR1000 (Manual CR1000, Campbell Scientific).<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/cr1000x-partes.png&#8221; title_text=&#8221;cr1000x partes&#8221; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Figura 2.\u00a0<\/strong>Panel de cableado del CR1000x (Manual CR1000x, Campbell Scientific).<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<h4>1.2. Instalaci\u00f3n y montaje del datalogger<\/h4>\n<p>El datalogger deber\u00e1 estar alojado al interior de una caja de intemperie (Figura 3). En el interior tambi\u00e9n ir\u00e1 el sensor de presi\u00f3n, el m\u00f3dem y la unidad de almacenamiento de energ\u00eda PS100 o PS150 para la alimentaci\u00f3n. La caja deber\u00e1 estar preparada para montarse en la estructura por medio de abrazaderas. La placa de montaje interna deber\u00e1 disponer de las perforaciones respectivas para asegurar el adecuado montaje de los equipos.<\/p>\n<p>Dispondr\u00e1 de un pasa-cables para prevenir la presurizaci\u00f3n y equilibrar las presiones dentro y fuera de la caja, necesario cuando se utilizan sensores de presi\u00f3n.<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/instalacion-datalogger-2.png&#8221; title_text=&#8221;instalacion datalogger 2&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; width=&#8221;80%&#8221; max_width=&#8221;80%&#8221; module_alignment=&#8221;center&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Figura 3. <\/strong>Gabinete de intemperie.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;25px||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Cada caja debe contemplar el cableado interno, el perif\u00e9rico y el m\u00f3dem para las comunicaciones.<\/p>\n<p>Para la conexi\u00f3n el\u00e9ctrica a tierra se debe utilizar una varilla para tierra de 5\/8 por 1,5 m (barra copper) y un conector para la varilla de tierra de 5\/8.<\/p>\n<h4>1.3. Absorbente de humedad<\/h4>\n<p>Para proteger los equipos de la corrosi\u00f3n y de da\u00f1os a los componentes electr\u00f3nicos por presencia de humedad en su interior es importante incluir en el interior de la caja bolsas de papel o g\u00e9nero con desecante para absorber la humedad. Se recomienda utilizar SilicaGel con indicador de humedad, \u00e9sta generalmente presenta un color azul cuando se encuentra en estado activo, y rosa cuando se satura. De esta forma es f\u00e1cil determinar la necesidad de renovar el desecante.<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/instalacion-datalogger-3.png&#8221; title_text=&#8221;instalacion datalogger 3&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; width=&#8221;90%&#8221; module_alignment=&#8221;center&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Figura 4. <\/strong>Conexi\u00f3n del datalogger CR1000 al sistema de alimentaci\u00f3n.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<h3>2. Software de la unidad central<\/h3>\n<h4>2.1. Loggernet<\/h4>\n<p>Loggernet es una unidad de peque\u00f1os programas que facilitan la configuraci\u00f3n, uso y captura de datos utilizando datalogger marca Campbell Scientific. Al activar el software se despliega en la pantalla una barra de herramientas en la cual se accede a cada una de las opciones que ofrece el Software Loggernet (Figura 5).<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/loggernet.png&#8221; title_text=&#8221;loggernet&#8221; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Figura 5<\/strong><strong>. <\/strong>Barra de herramientas de Loggernet.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<h4>2.2. Conexi\u00f3n del datalogger a la computadora<\/h4>\n<p>Como se debe suponer, para la conexi\u00f3n del datalogger a la computadora debe existir un medio f\u00edsico. Campbell ofrece varias soluciones a este requerimiento, como conexi\u00f3n directa con cables espec\u00edficos, conexi\u00f3n inal\u00e1mbrica v\u00eda m\u00f3dem, conexi\u00f3n inal\u00e1mbrica v\u00eda radio. Para comprobar el funcionamiento del CR1000 y cargar el software se debe utilizar una conexi\u00f3n directa mediante un cable de comunicaci\u00f3n serial que conecte el puerto RS232 del CR1000 con el PC. Se recomienda tener especial cuidado en utilizar un computador que est\u00e9 en buenas condiciones para evitar exponer el equipo a sobrecargas de voltaje.<\/p>\n<p>Loggernet, en la aplicaci\u00f3n &#8220;EZsetup&#8221; ofrece una opci\u00f3n que incluye varios pasos del tipo asistente de instalaci\u00f3n y que gu\u00eda al usuario para la identificaci\u00f3n de las caracter\u00edsticas de conexi\u00f3n y la comunicaci\u00f3n con que se dejar\u00e1 definido el equipo que se desea conectar (Figura 6).<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/instalacion-datalogger-5.png&#8221; title_text=&#8221;instalacion datalogger 5&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Figura 6. <\/strong>Inicio del asistente EZsetup de Loggernet.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>Se incluye una breve descripci\u00f3n de las tareas a realizar en cada paso con el fin de lograr una conexi\u00f3n exitosa entre la computadora y el datalogger.<\/p>\n<ul>\n<li>\u00a0<em>Introduction<\/em>: En esta pantalla s\u00f3lo se presenta informaci\u00f3n resumida respecto del proceso.<\/li>\n<li><em>Communication Setup<\/em>: Esta secci\u00f3n se compone de tres sub-pasos:\n<ul>\n<li>Primero hay que seleccionar de la lista el modelo del datalogger, en este caso se ha seleccionado el datalogger CR1000 y se digita el nombre que se asignar\u00e1 a esta estaci\u00f3n (deber\u00e1 consultar con el coordinador central de la red que administra los nombres de las estaciones), y presionar el bot\u00f3n next.<\/li>\n<li>Segundo se debe seleccionar de la lista el modo de comunicaci\u00f3n en este caso: Direct connect.<\/li>\n<li>Tercero se debe seleccionar el puerto COM del computador, si el computador posee s\u00f3lo un puerto serial seleccione COM1.<\/li>\n<\/ul>\n<\/li>\n<li>Datalogger settings: Se debe considerar lo siguiente:\n<ul>\n<li>Primero definir el par\u00e1metro de la velocidad de transmisi\u00f3n entre el datalogger y la computadora, com\u00fanmente se utiliza 9600 bits por segundo.<\/li>\n<li>Segundo deber\u00e1 definirse el identificador del equipo que corresponde a la direcci\u00f3n \u00fanica que tendr\u00e1 \u00e9ste dentro de la red &#8220;Pakbus ardes&#8221;, por lo cual se recomienda corroborar que sea \u00fanico. En este caso es conveniente asignar el n\u00famero serial que trae cada equipo sin desmedro de consultar al coordinador general de la red.<\/li>\n<\/ul>\n<\/li>\n<li>Setup Summary: En esta ventana se muestra un resumen de las opciones seleccionadas en los pasos anteriores, compruebe cada uno de los datos y luego presione el bot\u00f3n Finish.<\/li>\n<\/ul>\n<p>Las opciones del asistente de configuraci\u00f3n para enviar un programa, y horario de recolecci\u00f3n de datos se explicar\u00e1n en la siguiente secci\u00f3n.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<h4>2.3. Carga del programa en el datalogger<\/h4>\n<p>Luego de realizar con \u00e9xito la conexi\u00f3n del datalogger y haber descargado el programa de Internet, se debe traspasar el software de la computadora al datalogger para que \u00e9ste inicie la recolecci\u00f3n de los datos.<\/p>\n<p>Para realizar esta tarea se utilizar\u00e1 la aplicaci\u00f3n Connect de Loggernet (Figura 7), en donde se deber\u00e1 seleccionar el datalogger de la lista de la izquierda y luego presionar el bot\u00f3n Connect. Si el bot\u00f3n cambia su texto a Disconnect la conexi\u00f3n ha sido exitosa. Para enviar el programa se presiona el bot\u00f3n Send y luego se busca dentro de las carpetas el programa descargado y se selecciona. <strong>Se debe tener especial cuidado en este paso ya que al reemplazar el programa se pierden todos los datos que no hayan sido recolectados en ese momento, por esta raz\u00f3n si el datalogger ya estuvo operando se deber\u00e1n recolectar los datos antes de cambiar el programa, para esto presione el bot\u00f3n Colect Now.<\/strong><\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/loggernet-2.png&#8221; title_text=&#8221;loggernet 2&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Figura 7. <\/strong>Ventana de conexi\u00f3n de Loggernet.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>La aplicaci\u00f3n Loggernet proporciona una manera de comprobar el correcto funcionamiento del datalogger y los sensores antes de instalar los equipos en terreno. Para esto deber\u00e1 conectar los sensores al datalogger CR1000 seg\u00fan las especificaciones que se le indiquen, lo cual depender\u00e1 de los sensores utilizados en la estaci\u00f3n. Una vez conectados y energizados los sensores y el datalogger, active la aplicaci\u00f3n Connect de Loggernet. Luego, deber\u00e1 seleccionar la tabla Public para ver los datos en tiempo real (Figura 8).<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/connect.png&#8221; title_text=&#8221;connect&#8221; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Figura 8. <\/strong>Ventana de despliegue de datos de Loggernet.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p>En el cuadro 2 se presentan valores de comparaci\u00f3n de par\u00e1metros clim\u00e1ticos para un d\u00eda t\u00edpico de mediados de diciembre, tomados de una estaci\u00f3n ubicada en las cercan\u00edas de Chill\u00e1n.<\/p>\n<p>[\/et_pb_text][et_pb_text admin_label=&#8221;Texto imagen&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; text_font_size=&#8221;13px&#8221; text_line_height=&#8221;1.2em&#8221; text_orientation=&#8221;center&#8221; custom_margin=&#8221;||5px||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<p><strong>Cuadro 2.<\/strong> Valores de par\u00e1metros clim\u00e1ticos para un d\u00eda t\u00edpico de mediados de diciembre, Chill\u00e1n.<\/p>\n<p>[\/et_pb_text][et_pb_image src=&#8221;http:\/\/sitios.inia.cl\/agrometeorologia\/wp-content\/uploads\/sites\/44\/2023\/02\/instalacion-datalogger-8.png&#8221; title_text=&#8221;instalacion datalogger 8&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; admin_label=&#8221;Imagen manual&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px|0px|0px|0px|false|false&#8221; custom_padding=&#8221;0px|0px|0px|0px|false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; text_orientation=&#8221;right&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<h4 style=\"text-align: left\"><strong>Video de apoyo:<\/strong><\/h4>\n<p>[\/et_pb_text][et_pb_video src=&#8221;https:\/\/youtu.be\/nojV6ASmGOw&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; theme_builder_area=&#8221;post_content&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;][\/et_pb_video][et_pb_video admin_label=&#8221;perforacion de letreros&#8221; _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; width=&#8221;100%&#8221; width_tablet=&#8221;70%&#8221; width_phone=&#8221;70%&#8221; width_last_edited=&#8221;on|phone&#8221; module_alignment=&#8221;right&#8221; border_width_all=&#8221;1px&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/et_pb_video][et_pb_text _builder_version=&#8221;4.14.7&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;]<\/p>\n<h4>M\u00e1s informaci\u00f3n<\/h4>\n<ul>\n<li><a href=\"https:\/\/www.campbellsci.es\/cr1000\" target=\"_blank\" rel=\"noopener\">Datalogger CR1000 &#8211; Campbell Scientific<\/a><\/li>\n<li><a href=\"https:\/\/www.campbellsci.es\/cr1000x\" target=\"_blank\" rel=\"noopener\">Datalogger CR1000X &#8211; Campbell Scientific<\/a><\/li>\n<li><a href=\"https:\/\/www.campbellsci.es\/loggernet\" target=\"_blank\" rel=\"noopener\">Software Loggernet &#8211; Campbell Scientific<\/a><\/li>\n<li><a href=\"https:\/\/www.campbellsci.es\/pc400\" target=\"_blank\" rel=\"noopener\">Software PC400 &#8211;\u00a0 Campbell Scientific<\/a><\/li>\n<\/ul>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>","protected":false},"excerpt":{"rendered":"<p>Este manual detalla la instalaci\u00f3n y montaje del datalogger en el gabinete, adem\u00e1s de su configuraci\u00f3n mediante el programa PC400.<\/p>","protected":false},"author":45,"featured_media":1221,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","ngg_post_thumbnail":0,"footnotes":""},"categories":[145],"tags":[212,214,40,158,219,220,221,222],"acf":[],"_links":{"self":[{"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/posts\/3078"}],"collection":[{"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/users\/45"}],"replies":[{"embeddable":true,"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/comments?post=3078"}],"version-history":[{"count":15,"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/posts\/3078\/revisions"}],"predecessor-version":[{"id":3536,"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/posts\/3078\/revisions\/3536"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/media\/1221"}],"wp:attachment":[{"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/media?parent=3078"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/categories?post=3078"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sitios.inia.cl\/agrometeorologia\/en\/wp-json\/wp\/v2\/tags?post=3078"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}